Simultaneous/selective voltammetric detection of diclofenac and tetracycline in water on graphene modified-boron-doped diamond electrode

The graphene oxide modified boron-doped diamond electrode (GO/BDD) was obtained electrochemically and tested by cyclic voltammetry (CV) to detect diclofenac (DCF) from antiinflammatory pharmaceuticals class and tetracycline (TC) from antibiotics one, which belongs to emerging pollutants from water....

Teljes leírás

Elmentve itt :
Bibliográfiai részletek
Szerzők: Negrea Sorina-Claudia
Nicorescu Valeria
Neidoni Dorian Gabriel
Pacala Adina
Baciu Anamaria
Motoc Sorina
Manea Florica
Testületi szerző: International Symposium on Analytical and Environmental Problems (27.) (2021) (Szeged)
Dokumentumtípus: Könyv része
Megjelent: University of Szeged Szeged 2021
Sorozat:Proceedings of the International Symposium on Analytical and Environmental Problems 27
Kulcsszavak:Elektrokémia
Tárgyszavak:
Online Access:http://acta.bibl.u-szeged.hu/75992
LEADER 01891naa a2200301 i 4500
001 acta75992
005 20220808154028.0
008 220601s2021 hu o 1|| eng d
020 |a 978-963-306-835-9 
040 |a SZTE Egyetemi Kiadványok Repozitórium  |b hun 
041 |a eng 
100 1 |a Negrea Sorina-Claudia 
245 1 0 |a Simultaneous/selective voltammetric detection of diclofenac and tetracycline in water on graphene modified-boron-doped diamond electrode  |h [elektronikus dokumentum] /  |c  Negrea Sorina-Claudia 
260 |a University of Szeged  |b Szeged  |c 2021 
300 |a 303-307 
490 0 |a Proceedings of the International Symposium on Analytical and Environmental Problems  |v 27 
520 3 |a The graphene oxide modified boron-doped diamond electrode (GO/BDD) was obtained electrochemically and tested by cyclic voltammetry (CV) to detect diclofenac (DCF) from antiinflammatory pharmaceuticals class and tetracycline (TC) from antibiotics one, which belongs to emerging pollutants from water. Graphene reduced electrochemically from its oxide showed enhanced sensitivity in determining individual and selective or simultaneous of DCF and TC. The cyclic voltammetry method - based protocol for selective/simultaneous detection of DCF and TC was developed in this study using a commercial boron-doped diamond (BDD) electrode modified with graphene oxide (GO). 
650 4 |a Természettudományok 
650 4 |a Kémiai tudományok 
695 |a Elektrokémia 
700 0 1 |a Nicorescu Valeria  |e aut 
700 0 1 |a Neidoni Dorian Gabriel  |e aut 
700 0 1 |a Pacala Adina  |e aut 
700 0 1 |a Baciu Anamaria  |e aut 
700 0 1 |a Motoc Sorina  |e aut 
700 0 1 |a Manea Florica  |e aut 
710 |a International Symposium on Analytical and Environmental Problems (27.) (2021) (Szeged) 
856 4 0 |u http://acta.bibl.u-szeged.hu/75992/1/proceedings_of_isaep_2021_303-307.pdf  |z Dokumentum-elérés